Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Virol ; 96(2): e29409, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38293790

RESUMO

Persistent infection with high-risk types of human papillomaviruses (HPV) is a major cause of cervical cancer, and an important factor in other malignancies, for example, head and neck cancer. Despite recent progress in screening and vaccination, the incidence and mortality are still relatively high, especially in low-income countries. The mortality and financial burden associated with the treatment could be decreased if a simple, rapid, and inexpensive technology for HPV testing becomes available, targeting individuals for further monitoring with increased risk of developing cancer. Commercial HPV tests available in the market are often relatively expensive, time-consuming, and require sophisticated instrumentation, which limits their more widespread utilization. To address these challenges, novel technologies are being implemented also for HPV diagnostics that include for example, isothermal amplification techniques, lateral flow assays, CRISPR-Cas-based systems, as well as microfluidics, paperfluidics and lab-on-a-chip devices, ideal for point-of-care testing in decentralized settings. In this review, we first evaluate current commercial HPV tests, followed by a description of advanced technologies, explanation of their principles, critical evaluation of their strengths and weaknesses, and suggestions for their possible implementation into medical diagnostics.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Papillomavirus Humano , Infecções por Papillomavirus/complicações , Papillomaviridae/genética , Tecnologia
2.
Anal Bioanal Chem ; 415(6): 1065-1085, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36289102

RESUMO

Cancer is a genetic disease induced by mutations in DNA, in particular point mutations in important driver genes that lead to protein malfunctioning and ultimately to tumorigenesis. Screening for the most common DNA point mutations, especially in such genes as TP53, BRCA1 and BRCA2, EGFR, KRAS, or BRAF, is crucial to determine predisposition risk for cancer or to predict response to therapy. In this review, we briefly depict how these genes are involved in cancer, followed by a description of the most common techniques routinely applied for their analysis, including high-throughput next-generation sequencing technology and less expensive low-throughput options, such as real-time PCR, restriction fragment length polymorphism, or high resolution melting analysis. We then introduce benefits of electrochemical biosensors as interesting alternatives to the standard methods in terms of cost, speed, and simplicity. We describe most common strategies involved in electrochemical biosensing of point mutations, relying mostly on PCR or isothermal amplification techniques, and critically discuss major challenges and obstacles that, until now, prevented their more widespread application in clinical settings.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Mutação Puntual , Mutação , Neoplasias/diagnóstico , Neoplasias/genética , DNA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Predisposição Genética para Doença
3.
Talanta ; 238(Pt 2): 123064, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801892

RESUMO

Current molecular diagnostics of prostate cancer relies on detection of elevated levels of PSA protein in serum, but its specificity has been questioned due to its higher levels also in non-malignant prostate diseases. A long non-coding RNA biomarker, PCA3, demonstrated excellent specificity for prostate cancer, and thus has become an interesting alternative to PSA monitoring. Its detection utilizes mostly reverse transcription PCR with optical detection, making the protocol longer and more expensive. To avoid PCR, we have developed an electrochemical assay coupled with LAMP, an isothermal amplification technique showing high sensitivities at constant temperatures and shorter reaction times. We amplified PCA3 RNA as well as PSA mRNA (serving as a control), hybridized LAMP products on magnetic beads and measured them with chronoamperometry at carbon electrode chips. We show good sensitivity and specificity for both biomarkers in prostate cancer cell lines, and successful detection of PCA3 in clinical samples, i.e., urine samples from 11 prostate cancer patients and 7 healthy controls, where we obtained excellent correlation with clinical data. This is to our knowledge a first such attempt to apply electrochemistry to determine two RNA biomarkers directly in urine samples of prostate cancer patients in a minimally invasive diagnostics format.


Assuntos
Antígenos de Neoplasias , Neoplasias da Próstata , Antígenos de Neoplasias/genética , Biomarcadores , Biomarcadores Tumorais/genética , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/genética , RNA , Sensibilidade e Especificidade
4.
Anal Chim Acta ; 1187: 339145, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34753575

RESUMO

Electrochemical (EC) detection of DNA biomarkers represents an interesting tool in molecular oncology due to its sensitivity, simplicity, low cost or rapid times of measurement. However, majority of EC assays, same as most optical-based techniques, require preceding DNA extraction step to remove other cellular components, making these assays more laborious and time-consuming. One option to circumvent this is to use LAMP (loop-mediated amplification), an isothermal amplification technique that can amplify DNA directly in crude lysates in a short time at a constant temperature. Here, we coupled the LAMP reaction with EC readout to detect DNA from the two most common oncogenic human papillomavirus (HPV) types that cause cervical cancer in women, i.e. HPV 16 and HPV 18, directly in crude lysates without a need for DNA extraction step. We show that in crude lysates, the LAMP reaction was superior to PCR, with very good selectivity on a panel of cancer cell lines and with high sensitivity, enabling detection of HPV DNA from as few as 10 cells. As a proof of principle, we applied the assay to nineteen clinical samples both from uninfected women and from women suffering from cervical precancerous lesions caused by HPV 16 or HPV 18 genotypes. Clinical samples were simply boiled for 5 min in homogenization buffer without DNA extraction step, and amplified with LAMP. We obtained excellent concordance of our assay with PCR, reaching 100% sensitivity for both genotypes, 81.82% specificity for HPV 16 and 94.12% specificity for HPV 18. Proposed assay could be a straightforward, simple, rapid and sensitive alternative for early diagnostics of precancerous cervical lesions.


Assuntos
Infecções por Papillomavirus , Bioensaio , Feminino , Papillomavirus Humano 18/genética , Humanos , Técnicas de Amplificação de Ácido Nucleico , Papillomaviridae/genética , Infecções por Papillomavirus/diagnóstico
5.
Anal Bioanal Chem ; 412(21): 5031-5041, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31745609

RESUMO

This paper reports a simple electrochemical strategy for the determination of microRNAs (miRNAs) using a commercial His-Tag-Zinc finger protein (His-Tag-ZFP) that binds preferably (but non-sequence specifically) RNA hybrids over ssRNAs, ssDNAs, and dsDNAs. The strategy involves the use of magnetic beads (His-Tag-Isolation-MBs) as solid support to capture the conjugate formed in homogenous solution between His-Tag-ZFP and the dsRNA homohybrid formed between the target miRNA (miR-21 selected as a model) and a biotinylated synthetic complementary RNA detector probe (b-RNA-Dp) further conjugated with a streptavidin-horseradish peroxidase (Strep-HRP) conjugate. The electrochemical detection is carried out by amperometry at disposable screen-printed carbon electrodes (SPCEs) (- 0.20 V vs Ag pseudo-reference electrode) upon magnetic capture of the resultant magnetic bioconjugates and H2O2 addition in the presence of hydroquinone (HQ). The as-prepared biosensor exhibits a dynamic concentration range from 3.0 to 100 nM and a detection limit (LOD) of 0.91 nM for miR-21 in just ~ 2 h. An acceptable discrimination was achieved between the target miRNA and other non-target nucleic acids (ssDNA, dsDNA, ssRNA, DNA-RNA, miR-122, miR-205, and single central- or terminal-base mismatched sequences). The biosensor was applied to the analysis of miR-21 from total RNA (RNAt) extracted from epithelial non-tumorigenic and adenocarcinoma breast cells without target amplification, pre-concentration, or reverse transcription steps. The versatility of the methodology due to the ZFP's non-sequence-specific binding behavior makes it easily extendable to determine any target RNA only by modifying the biotinylated detector probe.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , MicroRNAs/análise , Dedos de Zinco , Linhagem Celular , Linhagem Celular Tumoral , Humanos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...